Marvair Marine MAB models are the world's premier line of self-contained reverse cycle air
conditioners. Reverse cycle means that they provide heating in the winter and cooling in the summer.
The units are built with capacities of 7,000; 10,000; 12,000 & 16,000, & 24,000 BTUHs. (For
information our 5,000 BTUH unit, the SAB05, click here). The MAB units use R-410A refrigerant.
R-410A is environmentally friendly, non-ozone depleting and accepted for use by the European
Community. All Marvair self-contained units meet all applicable ABYC, US Coast Guard, CE directives
and are built to the requirements of UL standard 484, 7th Edition. Marvair units are designed for
operation on 60 Hz. & 50 Hz. power supplies and various voltages.
| Structural supports, blower housing and the control box are constructed of light weight, superior corrosion resistant aluminum primed and finished with a white, heat cured polyester |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Stainless steel drain pan with embossed bottom adds rigidity and keeps critical components above condensate. |
![]() |
![]() |
|
![]() |
A universal control/PC board
One control board for all products - self-contained units, split systems, chillers and chilled water air handlers- makes replacement quicker and easier and reduces stocking requirements.
A Marvair first - the Box Blower air mover
|
|
- Mounting holes for the compressor are punched and tapped- no welds that can rust.
- The bottom of the pan is insulated to prevent external condensation, minimize movement and reduce sound transmission.
- Multi-wire control box harness allows for remote mounting of the control box up to six feet from the unit.
- Terminal strip for both the power & control wiring.
- 5/8" condensate hose barbs provided for either end of the base pan.
- Factory provided hold down clamps.
Accessories/Options
- Water pump kit
- Supply & return grilles
|
Downloadable Literature
Get the latest version of Adobe Acrobat Reader here.
Instructions for Downloading Marvair Literature
In order to quickly download a pdf, please right-click on the file name and then save to your hard drive. After saving to your hard drive, then open the pdf using Adobe Acrobat and either print or view. At times, attempting to open a file instead of downloading can cause the file to open very slowly or stall at a certain point. Also, firewalls or anti-virus programs can cause errors or stalls. If you have problems downloading any Marvair files, please contact us at marvair@airxcel.com and we can send the file to you via e-mail. For Technical Literature such as drawings and schematics, please visit www.marvairmarine.net. |
|