Classic AVPA
Classic I3 The Classic heat pumps, models AVPA, are built in nominal cooling capacities of 2 to 5 tons (24,000 to 55,000 BTUH's). Each of the units is available with electric resistant heat as second stage or emergency heat. All AVPA series heat pumps use R-410A refrigerant. Scroll compressors are standard on all models. EER's up to 11.1. A complete range of factory installed ventilation options are available including the GreenWheel® ERV. Standard controls include:
  • Defrost control - automatically removes ice or frost on the outdoor coil during cold weather.
  • High refrigerant pressure switch with lockout relay - Turns the unit off to protect the compressor if the refrigerant pressure exceeds the specified set point. A manual reset is required to prevent destructive short cycling.
  • Loss of charge switch with lockout relay - Turns the unit off to protect the compressor if the refrigerant pressure drops below the specified set point. A manual reset is required to prevent harmful short cycling.
Optional Functions & Controls:
  • Dehumidification: Hot gas reheat or electric reheat are offered to control humidity levels in the classroom.
  • Low ambient control - allows unit to operate in the cooling mode when outdoor ambient temperatures are low.
  • Hard start kit - Used on single phase units to compressor higher starting torque when voltage is low. Note: not recommended for use on scroll compressors.
  • Adjustable outdoor thermostat - Will not allow electric resistant heat to be energized unless outdoor temperatures are below a specified set point.
  • "S" circuit - Limits the electric demand by preventing the simultaneous operation of the compressor and the electric heat.
  • Compressor time delay - Prevents the compressor from restarting immediately after an interruption of power. The delay interval is adjustable from 12 seconds to 8 minutes.
  • Many more.
  • Accessories include:
    • Supply grilles
    • Return grilles
    • Return air filter grilles
    • Thermostats

Downloadable Literature
Get the latest version of Adobe Acrobat Reader here.

Instructions for Downloading Marvair Literature
In order to quickly download a pdf, please right-click on the file name and then save to your hard drive. After saving to your hard drive, then open the pdf using Adobe Acrobat and either print or view. At times, attempting to open a file instead of downloading can cause the file to open very slowly or stall at a certain point. Also, firewalls or anti-virus programs can cause errors or stalls. If you have problems downloading any Marvair files, please contact us at marvair@airxcel.com and we can send the file to you via e-mail.


Copyright© 2011 Marvair. All Rights Reserved.
156 Seedling Drive, Cordele, GA 31015 . 229.273.3636 - Toll Free | 800.841.7854